Development, Validation, and Clinical Applicability of Predictive Models for Pediatric Sepsis: A Critical Systematic Review of the Literature (2021–2026)

44 views

Tags : pediatricsepsis;septicshock;earlydetection;supervi

Category : Review articles

Authors : Ahmed Haddadi

Full text (PDF file)

Background. Pediatric sepsis remains a leading cause of preventable death. The 2024 international consensus revision removed systemic inflammatory response syndrome from the diagnostic framework and adopted a definition based on organ dysfunction associated with suspected or confirmed infection, operationalised by the Phoenix Sepsis Score. This recalibration shifts the clinical problem from the recognition of established organ dysfunction to its anticipation [3,4,5,6]. Objective. To appraise systematically the studies addressing the development and validation of predictive models for sepsis in children and neonates, characterising their discriminative performance, the robustness of validation, and the clinical transferability of the proposed instruments. Sources and selection. PubMed/MEDLINE was searched (January 2021 – November 2026). Derivation studies, external validations, evaluations of devices in clinical deployment, and systematic reviews, meta-analyses and scoping reviews were eligible. Thirty-four studies were included. Data were extracted using a structured framework: source population and level of care; operational definition of sepsis; type of model employed and number of covariates; measures of discrimination and calibration with their confidence intervals; level of validation; and identified sources of bias. Synthesis of findings. An umbrella review of 18 systematic reviews reports a pooled sensitivity of 0.81 (95% CI 0.76–0.85) and a specificity of 0.79 (95% CI 0.74–0.84), with areas under the curve ranging from 0.78 to 0.94 according to resource setting [1]. Individual studies range from 0.56 to 0.99 [22]. Three quarters of neonatal models (34 of 44) have undergone only a single validation [23]. Evaluation of a clinically deployed device, encompassing 166,943 emergency department encounters, demonstrated a sensitivity of 36% (95% CI 29–43%) and a positive predictive value of 3%, with lower sensitivity among children of sub-Saharan African ancestry, children under 5 years of age, and those managed outside tertiary pediatric centres [2]. Conclusion. The dissociation between performance measured in research settings and that observed in deployment — from 94% to 36% sensitivity — is the structuring finding of this review. The narrow margin separating complex algorithms from parsimonious models indicates that predictive performance depends less on algorithmic complexity than on the quality of covariates, the repetition of external validations, and equity of performance across subpopulations.